Sensors : End of Lap
Summary
The sensor information shown on this page is legacy information only.
Jacobs Design does not supply any of these sensors.

Beacon Sensor
End of Lap Beacon
Power Supply 10 to 14 Volts DC @ 150 mA

Click to Enlarge

Output Modulated Infra Red beam
Temperature Limits 20 to 60 dec C
Connections
White +12 Volts
Black Battery Negative
Range Fifteen meters
Mounting Arrangement

The End of Lap Beacon mounts on a suitable stand or on the pit wall facing the track. It should be at about the same level as the detector in the car. This is not critical unless the distance to the car is less than three meters.

Important Note

When packing to go home, ensure you collect the beacon. It is common for it to be left at the thrack.

End of Lap Sensor
Power Supply 8 Volts DC

Click to Enlarge

Output Signal 12 Volt Pulse
Temperature Limits 20 to 60 dec C
Connections
A +8V Red
B signal Blue
C common Black
Mounting Arrangement

The End of Lap sensor mounts on the side of the vehicle facing the Beacon. It should be tilted about 10 to 15 degress towards the ground in order to prevent it being saturated by direct sunlight.

Test

Operation can be checked by using the test switch on the beaconor by waving the beacon past the sensor. This should cause the indicator on the sensor to blink, and a status change from 0 to 1 can be noticed on the MSELog Test Sensors display.

Logger Configuration

Select Lap Marker from the sensor name menu. It is OK for the sample rate to be 0 for this point.